3 Phase Low Voltage Protection Devices AC DC Contactors 50Hz / 60Hz 1000V
CJX2(LC1-D09) Series AC Contactors |
Application |
CJX2(LC1-D09) series A.C.contactor are suitable for frequency 50/60Hz, rated insulation voltage
up to 1000V, rated operation current 9~330A under AC-3duty. It is mainly used for making/breaking
electric circuits at along distance & for frequent starting/stopping & controlling A.C.Motors. It is used
in combination with thermal relay to compose a magnetic motor starter, so. The products accords with
such standards as IEC60947-4-1 & GB14048.4. |
Technical parameter |
Rated operational voltage & rated insulation voltage of the contactor see table1. |
Model |
Rated operating voltage(V) |
Rated operating voltage(V) |
CJX2-9~95 |
220~660 |
220~1000 |
CJX2-115~330 |
660 |
1000 |
|
Conventional thermal current and rated operating current and maximum power of controllable 3-phase |
A.C.motor under AC-3 duty see Table 2. |
Model |
Conventional
thermal current(A) |
Rated operating voltage(V) |
Rated operating voltage(V) |
380V |
660V |
1000V |
380V |
660V |
1000V |
CXJ2-9 |
20 |
9 |
6.6 |
|
4 |
5.5 |
|
CXJ2-12 |
20 |
12 |
8.9 |
|
5.5 |
7.5 |
|
CXJ2-18 |
32 |
16 |
10.6 |
|
7.5 |
9 |
|
CXJ2-25 |
40 |
25 |
18 |
|
11 |
15 |
|
CXJ2-32 |
50 |
32 |
21 |
|
15 |
18.5 |
|
CXJ2-40 |
60 |
40 |
34 |
|
18.5 |
30 |
|
CXJ2-50 |
80 |
50 |
39 |
|
22 |
33 |
|
CXJ2-65 |
80 |
65 |
42 |
|
30 |
37 |
|
CXJ2-80 |
125 |
80 |
49 |
|
37 |
45 |
|
CXJ2-95 |
125 |
95 |
49 |
|
45 |
45 |
|
CXJ2-115 |
200 |
115 |
65 |
40 |
55 |
80 |
65 |
CXJ2-150 |
200 |
150 |
80 |
50 |
75 |
100 |
65 |
CXJ2-185 |
275 |
185 |
95 |
65 |
90 |
110 |
100 |
CXJ2-225 |
275 |
225 |
115 |
80 |
110 |
129 |
100 |
CXJ2-265 |
315 |
265 |
150 |
95 |
132 |
160 |
147 |
CXJ2-330 |
380 |
330 |
185 |
115 |
160 |
220 |
160 |
|
Endurance is shown in table 3. |
Model |
Frequency of operation(1/h) |
Frequency of operation(1/h) |
Frequency of operation(1/h) |
CJX2-9~25 |
1200 |
1200 |
100 |
CJX2-32~40 |
600 |
800 |
80 |
CJX2-50~65 |
60 |
CJX2-80~95 |
600 |
CJX2-115~150 |
1000 |
120 |
CJX2-185~225 |
600 |
100 |
CJX2-265~330 |
80 |
|
Voltage range of control coil:(0.85-1.1)US |
Technical date of the auxiliary contacts see table 4. |
Utilization category |
AC-15 |
|
AC-15 |
Rated insulation voltage(V) |
|
660 |
|
Rated operating voltage(V) |
380 |
|
220 |
Conventional thermal current(A) |
|
10 |
|
Rated operating current(A) |
0.95 |
|
0.15 |
Contarol capacity |
360VA |
|
33W |
|
Voltage of control coil power see Table 5 |
Model |
Control Voltage(V) |
Control capacity |
Staring(VA) |
Attracting(VA) |
CJX2-9~18 |
24,36,48,110,127,220,380 |
60 |
7 |
CJX2-25~32 |
90 |
7.5 |
CJX2-40~95 |
200 |
20 |
CJX2-115~150 |
110,127,220,380 |
660 |
54 |
CJX2-185~225 |
966 |
66 |
CJX2-265 |
110,127 |
7200 |
10 |
CJX2-330 |
220,380 |
840 |
12 |
|
|